Possible Contact Heart Rate Problems
In order to properly diagnose any problem with the conctact heart rate system, please refer to the following procedures.
This machine uses a hand ECG (Electrocardiogram) printed circuit board along with wires and a set of metal plates. The hand
ECG board is an integral part of the machine and is hidden inside.
Troubleshooting Check List – Table 2
Access to “Diagnostics” menu
To determine the condition of the various electrical and mechanical components, you will need to enter into the
DIAGNOSTICS menu as follows:
1. Turn power OFF.
2. Simultaneously hold down the speed INCREASE and DECREASE keys and turn power ON.
3. Release the speed INCREASE and DECREASE keys once entered into the Diagnostics menu.
4. Press JustGo
TM
/ENTER to access Diagnostic items.
When you access the Diagnostics menu, you will notice the following message: “TXXX VERSION”
The message above indicates the version of the computer software installed in your computer display monitor. This
information is helpful in diagnosing certain computer related conditions. Keep in mind that the version number may
change depending on the model number of your T700 treadmill.
The T700 treadmill allows you to perform the following tests :
To perform any one of the above procedures, press the Speed INCREASE or DECREASE keys to select the one you
want and press the JustGo
TM
/ENTER key to accept.
25
NVRAM TEST
EPROM TEST
KEYPAD TEST
DISPLAY TEST
SOUND TEST
HEART RATE TEST
BELT ALIGNMENT
MOTOR CHECK
ELEVATION CALIBRATION
STATISTICS
ERROR LOG
CURRENT TEST
SPEED SENSOR TEST
MAINTENANCE
CCoommppuutteerr DDiiaaggnnoossttiiccss
Computer Diagnostics
5
PROBLEM
No reading
Erratic reading
POSSIBLE CAUSE
Hands have not been in contact
with the metal plates long enough
Defective hand contact board
Wires are not connected properly
Hands may move too much on the plates
Defective board hand contact board
Strong neon lights too close to console
Interference with other signals
SOLUTION
Wait for 15-20 seconds before
a reading
Change ECG board
Verify Wiring
Do not move your hands
Change board
Move the climber
Use only this machine to verify